INDEPENDENT WATER CONSULTANCY · MARINE WATER MANAGEMENT · CREW EDUCATION
VORENICO / FLAG STATE WATER COMPLIANCE

Gibraltar · Potable Water & Yachts

Current Gibraltar MLC guidance with a risk-based Fresh Water Safety Plan, water production, bunkering and documented checks.

HOW THE MEMBER REGISTER WORKS

Four steps to a review-ready vessel dossier

Choose only your vessel's registered flag. The crew records what can be demonstrated; Vorenico assesses the relevant evidence and identifies outstanding actions.

  1. 01
    Describe the vessel

    Vessel name, commercial or private status, length, GT, year and applicable certificate/code.

  2. 02
    Choose a status

    Evidence supplied, action needed, not checked yet, or not applicable with a clear reason.

  3. 03
    Reference proof

    Enter a logbook page, inspection date, laboratory report ID, maintenance record or corrective action. This field is text only; documents are shared separately.

  4. 04
    Save and export

    Save your draft, export the CSV and share that register and source documents with Vorenico for review.

Example: Weekly water inspection → Evidence supplied → “Inspection 26 Oct 2026; deck logbook p.84; responsible engineer: Chief Engineer”.

OFFICIAL SOURCES · REVIEWED 28 OCTOBER 2026

Gibraltar Maritime Administration water compliance

Gibraltar MLN 014(b), issued 6 December 2024, supersedes MLN 014(a). Part 3 gives technical evidence-of-compliance guidance for loading, disinfecting, producing, storing and distributing potable water. It recommends a Fresh Water Safety Plan for complex systems, describes weekly inspection practice and distinguishes a 0.2 mg/L chlorine bunkering recommendation from a compulsory universal chlorine requirement. A published MLN is an accepted way to demonstrate compliance, but equivalent or higher alternative evidence may be considered.

Not a certificate

This evidence register is a member self-assessment tool; a recorded Vorenico technical review is not a statutory flag-state clearance.

Classification matters

Duty: binding if relevant regulation applies. Conditional: only under stated code and circumstances. Best practice: prudent engineering control, not an independent statutory limit. Review: confirm with the administration or applicable code before claiming compliance.

02 / Source-indexed evidence register

18 controls. A member-uploaded status is not verified, and N/A needs a reason.

GI01

Confirm Gibraltar registry and MLC applicability

Applicability

Review

Determine yacht category, commercial/pleasure use, seafarer status, GT, DMLC, applicable exemptions and accepted equivalences.

When in scope: All Gibraltar-registered yachts; commercial/pleasure applicability varies

Evidence requested: Registry, certificates, manning, DMLC and flag correspondence

GMLC · Scope; Regs 26–27 ↗

GI02

Provide fit-for-consumption drinking water

Supply

Duty

Provide safe drinking water in adequate quantity and quality, considering crew and voyage; check exact applicable paragraph.

When in scope: Where Gibraltar drinking-water regulation applies

Evidence requested: Lab results, drinking water production/transfer volumes, risk assessment

GMLC · Regulation 26 / relevant current provision ↗

GI03

Supply drinking water to seafarers without charge

Crew welfare

Duty

Food and drinking-water supply is provided free of charge during seafarers’ period of engagement.

When in scope: Seafarers covered by relevant MLC provision

Evidence requested: Crew supply arrangements, policy and accommodation facilities

GMLN24 · Key points 1; Part 2 §4 ↗

GI04

Document frequent master-authorised water inspections

Inspection

Conditional

MLN 014(b) describes inspections at intervals no greater than seven days as evidence of compliance. Confirm legal scope and equivalent inspection method.

When in scope: Ships subject to MLC checks and MLN 014(b) compliance method

Evidence requested: Weekly log dates, responsible person, corrective records

GMLN24 · Key points 4; Part 3 §18 ↗

GI05

Inspect water storage, handling and catering areas

Inspection

Conditional

Inspect drinking-water supplies and storage/handling equipment as well as relevant catering areas, under the authority of the master.

When in scope: Relevant vessel and inspection programme

Evidence requested: Documented scope, crew inspections and findings

GMLN24 · Part 3 §18 ↗

GI06

Apply a vessel-specific Fresh Water Safety Plan approach

Water Safety Plan

Best practice

Complete hazard analysis, source-to-tap treatment controls, monitoring and corrective actions; guidance recommends a FWSP, not a universal statutory certificate.

When in scope: Especially yachts with complex onboard systems

Evidence requested: System diagram, risk register and FWSP

GMLN24 · Part 3 §6(3) ↗

GI07

Use potable-only hoses for bunkering

Bunkering

Best practice

Mark, cap, drain, clean and stow dedicated hoses off deck; flush/discharge before use.

When in scope: Water taken from shore or barge

Evidence requested: Hose inventory, hygiene instructions, bunkering log

GMLN24 · Part 3 §7(1)–(2) ↗

GI08

Prevent potable and nonpotable cross-connection

Distribution

Best practice

Identify potable fill lines and physically prevent non-potable connections; verify independent supply pumps and pipe routing.

When in scope: Bunkering and internal distribution

Evidence requested: P&ID, line marking and backflow inspection

GMLN24 · Part 3 §7(3), §16 ↗

GI09

Provide failsafe alarm on primary automatic disinfection

Treatment

Conditional

Guidance calls for bypass protection and audible/visible fault detection, with a safe outcome on malfunction. Verify individual design and accepted alternatives.

When in scope: Where a primary automatic disinfection unit is installed

Evidence requested: Control philosophy, alarms, tests and commissioning

GMLN24 · Part 3 §8 ↗

GI10

Interpret 0.2 mg/L free chlorine as guidance, not blanket duty

Desinfection

Best practice

MLN states that routine bunkering chlorination is not required in every case; 0.2 mg/L free chlorine (or 1.0 mg/L chloramines if chloraminated) is described as good practice where appropriate.

When in scope: When chlorinating loaded potable water

Evidence requested: Residual tests, source details, dosing procedure and contact time

GMLN24 · Part 3 §9 ↗

GI11

Validate UV operation and limits of residual protection

UV

Best practice

UV lacks downstream residual action; provide appropriate intensity monitoring, alarms and maintenance, considering location and microbial growth in pipework.

When in scope: UV installed for drinking water treatment

Evidence requested: UV sizing, sensor data, lamp record and alarms

GMLN24 · Part 3 §12 ↗

GI12

Assess RO source quality, monitoring and diversion

Watermaking

Best practice

Assess marine intake pollution, prefiltration and product quality. Reliable online monitoring and rapid action are essential where RO is relied on as treatment.

When in scope: Seawater RO/watermaking installed

Evidence requested: RO operation procedures, conductivity, reject diversion and water testing

GMLN24 · Part 3 §14(1)–(6) ↗

GI13

Review mineralisation and corrosion effects of RO product

Watermaking

Best practice

Evaluate pH, corrosion and mineral stabilisation for demineralised seawater before long storage or distribution.

When in scope: Very low-mineral permeate entering tanks/distribution

Evidence requested: Water chemistry, materials assessment and conditioning logs

GMLN24 · Part 3 §14(7) ↗

GI14

Check potable tank design, access and rotation

Storage

Best practice

Tanks should be accessible, marked potable water, safely coated and operated in rotation to reduce stagnation; verify materials and vents.

When in scope: Potable water tanks under MLN Part 3

Evidence requested: Tank inventory, inspection schedule, drawings, coatings

GMLN24 · Part 3 §16 ↗

GI15

Assess two-day tank capacity in context

Storage

Review

Notice says storage should normally not be below two-day supply but can be adjusted for reliable onboard production. This is guidance, not an automatic absolute statutory threshold.

When in scope: Under MLN 014(b) storage guidance and actual vessel production

Evidence requested: Volume calculation, person numbers and verified watermaker capacity

GMLN24 · Part 3 §16 ↗

GI16

Maintain a risk-based planned maintenance programme

Maintenance

Best practice

Use manufacturer-based maintenance of UV, filters, tanks, calorifiers, outlets and hoses; distinguish illustrative notice intervals from mandatory legal frequencies.

When in scope: All onboard water production/distribution components

Evidence requested: PMS tasks, servicing logs and inspected deficiencies

GMLN24 · Part 3 §17 ↗

GI17

Record non-compliant samples and corrective actions

Incidents

Best practice

If monitoring shows unsafe water, consider isolate/alternative supply, investigate, repair and verify before return to service. Record owner, deadline and final test.

When in scope: All water systems with testing or incident programmes

Evidence requested: Incident log, lab reports, actions and return-to-service authority

GMLN24 · Part 3 §§6, 17–18 ↗

GI18

Clarify unusual Isle of Man reference in Gibraltar notice

Source quality

Review

The published Gibraltar MLN 014(b) has an apparent copy-edit reference to the Isle of Man official logbook in §18. Do not interpret this as a Gibraltar requirement to use a Manx logbook; obtain GMA clarification if relied upon.

When in scope: Gibraltar inspection records from MLN 014(b)

Evidence requested: GMA clarification, Gibraltar vessel official logbook and actual inspection format

GMLN24 · Part 3 §18 (logbook text) ↗

Editorial review: 28 October 2026. Flag State requirements are specific to the vessel, operating status, certificate, build date and accepted alternatives. Re-check the published code and flag/RO correspondence before claiming statutory compliance.